Kineski proizvođač CJM3-250 225A 35kA/25kA MCCB prekidač u lijevanom kućištu

Kratak opis:

Primjena

Automatski prekidač s lijevanim kućištem serije CJMM1 (u daljnjem tekstu: prekidač) primjenjuje se u AC 50/60HZ distributivnim mrežama s nazivnim naponom izolacije od 800V, nazivnim radnim naponom od 690V i nazivnom radnom strujom od 10A do 630A. Koristi se za distribuciju energije i sprječavanje oštećenja strujnih kola i opreme za napajanje uslijed preopterećenja, kratkog spoja, podnapona i drugih kvarova. Također se koristi za rijetko pokretanje motora, kao i zaštitu od preopterećenja, kratkog spoja i podnapona. Ovaj prekidač ima prednosti male zapremine, visoke prekidne moći, kratkog luka (ili bez luka) itd. Može biti opremljen priborom poput alarmnog kontakta, okidača za prekid, pomoćnog kontakta itd., idealan je proizvod za korisnika. Automatski prekidač za preostalu struju može se instalirati vertikalno (vertikalna instalacija) ili horizontalno (horizontalna instalacija). Proizvod je u skladu sa standardima IEC60947-2 i Gb140482.


Detalji o proizvodu

Oznake proizvoda

Model proizvoda

CJ:Kod preduzeća
M: Prekidač u lijevanom kućištu
1: Broj dizajna
□:Nazivna struja okvira
□:Kod karakteristike prekidne moći/S označava standardni tip (S se može izostaviti)H označava viši tip

Napomena: Postoje četiri tipa neutralnog pola (N pol) za četverofazni proizvod. Neutralni pol tipa A nije opremljen elementom za zaštitu od prekomjerne struje, uvijek je uključen i ne uključuje se ili isključuje zajedno s ostala tri pola.
Neutralni pol tipa B nije opremljen elementom za zaštitu od prekomjerne struje i uključuje se ili isključuje zajedno s ostala tri pola (neutralni pol se uključuje prije isključivanja). Neutralni pol tipa C je opremljen elementom za zaštitu od prekomjerne struje i uključuje se ili isključuje zajedno s ostala tri pola (neutralni pol se uključuje prije isključivanja). Neutralni pol tipa D je opremljen elementom za zaštitu od prekomjerne struje, uvijek je uključen i ne uključuje se ili isključuje zajedno s ostala tri pola.

Tabela 1

Naziv pribora Elektronsko otpuštanje Oslobađanje spoja
Pomoćni kontakt, okidač pod naponom, alarmni kontakt 287 378
Dva pomoćna seta kontakata, kontakt alarma 268 368
Isključivač, alarmni kontakt, pomoćni kontakt 238 348
Otpuštanje podnapona, kontakt alarma 248 338
Pomoćni kontakt alarmni kontakt 228 328
Kontakt alarma za okidanje napona 218 318
Pomoćni kontakt podnaponskog okidača 270 370
Dva pomoćna seta kontakata 260 360
Otpuštanje podnapona 250 350
Pomoćni kontakt za okidanje napona 240 340
Otpuštanje podnapona 230 330
Pomoćni kontakt 220 320
Isključivač 210 310
Kontakt alarma 208 308
Bez dodatne opreme 200 300

Klasifikacija

  • Po prekidnoj moći: a standardni tip (tip S) b tip sa većom prekidnom moći (tip H)
  • Po načinu povezivanja: a) priključak prednje ploče, b) priključak zadnje ploče, c) tip utikača
  • Po načinu rada: a direktno upravljanje ručicom, b upravljanje rotirajućom ručicom, c električno upravljanje
  • Po broju polova: 1P, 2P, 3P, 4P
  • Pomoću pribora: kontakt alarma, pomoćni kontakt, okidač napona, okidač podnapona

Normalni uslovi korištenja

  • Nadmorska visina mjesta instalacije ne smije prelaziti 2000 m
  • Temperatura okolnog zraka
  • Temperatura okolnog zraka ne smije prelaziti +40℃
  • Prosječna vrijednost ne smije prelaziti +35℃ u roku od 24 sata
  • Temperatura okolnog zraka ne smije biti niža od -5℃
  • Atmosferski uslovi:
  • Referentna vlažnost atmosfere ovdje ne smije prelaziti 50% na najvišoj temperaturi od +40℃, a može biti i viša na nižim temperaturama. Kada prosječna najniža temperatura u najvlažnijem mjesecu ne prelazi 25℃ može dostići 90%, mora se uzeti u obzir kondenzacija na površini proizvoda zbog promjene temperature.
  • Stepen zagađenja je 3. klase

Glavni tehnički parametar

1 Nazivna vrijednost prekidača
Model Imax (A) Specifikacije (A) Nazivni radni napon (V) Nazivni napon izolacije (V) Intenzivna intenzivna nega (kA) Ics (kA) Broj polova (P) Udaljenost luka (mm)
CJMM1-63S 63 6, 10, 16, 20
25, 32, 40,
50,63
400 500 10* 5* 3 ≤50
CJMM1-63H 63 400 500 15* 10* 3,4
CJMM1-100S 100 16, 20, 25, 32
40, 50, 63,
80.100
690 800 35/10 22/5 3 ≤50
CJMM1-100H 100 400 800 50 35 2, 3, 4
CJMM1-225S 225 100.125,
160,180,
200.225
690 800 35/10 25/5 3 ≤50
CJMM1-225H 225 400 800 50 35 2, 3, 4
CJMM1-400S 400 225.250,
315.350,
400
690 800 50/15 35/8 3,4 ≤100
CJMM1-400H 400 400 800 65 35 3
CJMM1-630S 630 400.500,
630
690 800 50/15 35/8 3,4 ≤100
CJMM1-630H 630 400 800 65 45 3
Napomena: Kada su parametri ispitivanja za 400V, 6A bez okidača za grijanje
2 Karakteristika inverznog vremenskog prekida kada je svaki pol prekostrujnog okidača za distribuciju energije uključen u isto vrijeme
Stavka ispitivanja Struja (I/In) Područje vremena testiranja Početno stanje
Struja neisključivanja 1,05 In 2h (n>63A), 1h (n<63A) Hladno stanje
Struja okidanja 1,3 In 2h (n>63A), 1h (n<63A) Odmah nastavite
nakon testa br. 1
3 Karakteristika inverznog prekidanja kada svaki pol preopterećenja
Istovremeno se uključuje i strujni relea za zaštitu motora.
Postavka Trenutno Konvencionalno vrijeme Početno stanje Napomena
1,0 inča >2 sata Hladno stanje
1,2 inča ≤2 sata Nastavljeno odmah nakon testa broj 1
1,5 inča ≤4 min Hladno stanje 10≤In≤225
≤8 minuta Hladno stanje 225≤In≤630
7,2 inča 4s≤T≤10s Hladno stanje 10≤In≤225
6s≤T≤20s Hladno stanje 225≤In≤630
4 Karakteristika trenutnog rada prekidača za distribuciju energije treba biti postavljena na 10in+20%, a prekidača za zaštitu motora na 12ln±20%

Veličina instalacije okvira

CJMM1-63, 100, 225, Dimenzije gabarita i instalacije (priključak na prednju ploču)

Veličine (mm) Kod modela
CJMM1-63S CJMM1-63H CJMM1-63S CJMM1-100S CJMM1-100H CJMM1-225S CJMM1-225
Veličine obrisa C 85,0 85,0 88,0 88,0 102.0 102.0
E 50,0 50,0 51,0 51,0 60,0 52,0
F 23,0 23,0 23,0 22,5 25,0 23,5
G 14,0 14,0 17,5 17,5 17,0 17,0
G1 6,5 6,5 6,5 6,5 11,5 11,5
H 73,0 81,0 68,0 86,0 88,0 103,0
H1 90,0 98,5 86,0 104,0 110,0 127,0
H2 18,5 27,0 24,0 24,0 24,0 24,0
H3 4.0 4,5 4.0 4.0 4.0 4.0
H4 7.0 7.0 7.0 7.0 5.0 5.0
L 135,0 135,0 150,0 150,0 165,0 165,0
L1 170,0 173,0 225,0 225,0 360,0 360,0
L2 117,0 117,0 136,0 136,0 144,0 144,0
W 78,0 78,0 91,0 91,0 106,0 106,0
W1 25,0 25,0 30,0 30,0 35,0 35,0
W2 - 100,0 - 120,0 - 142,0
W3 - - 65,0 65,0 75,0 75,0
Veličine instalacija A 25,0 25,0 30,0 30,0 35,0 35,0
B 117,0 117,0 128,0 128,0 125,0 125,0
od 3,5 3,5 4,5 4,5 5.5 5.5

CJMM1-400,630,800,Gabarske i instalacijske veličine (Priključak prednje ploče)

Veličine (mm) Kod modela
CJMM1-400S CJMM1-630S
Veličine obrisa C 127 134
C1 173 184
E 89 89
F 65 65
G 26 29
G1 13,5 14
H 107 111
H1 150 162
H2 39 44
H3 6 6,5
H4 5 7,5
H5 4,5 4,5
L 257 271
L1 465 475
L2 225 234
W 150 183
W1 48 58
W2 198 240
A 44 58
Veličine instalacija A1 48 58
B 194 200
Od 8 7

Dijagram izreza za spajanje zadnje ploče - Utikač

Veličine (mm) Kod modela
CJMM1-63S
CJMM1-63H
CJMM1-100S
CJMM1-100H
CJMM1-225S
CJMM1-225H
CJMM1-400S CJMM1-400H CJMM1-630S
CJMM1-630H
Veličine tipa utikača za priključke na zadnjoj ploči A 25 30 35 44 44 58
od 3,5 4,5*6
duboka rupa
3.3 7 7 7
od1 - - - 12,5 12,5 16,5
od2 6 8 8 8,5 9 8,5
oD 8 24 26 31 33 37
oD1 8 16 20 33 37 37
H6 44 68 66 60 65 65
H7 66 108 110 120 120 125
H8 28 51 51 61 60 60
H9 38 65,5 72 - 83,5 93
H10 44 78 91 99 106,5 112
H11 8,5 17,5 17,5 22 21 21
L2 117 136 144 225 225 234
L3 117 108 124 194 194 200
L4 97 95 9 165 163 165
L5 138 180 190 285 285 302
L6 80 95 110 145 155 185
M M6 M8 M10 - - -
K 50,2 60 70 60 60 100
J 60,7 62 54 129 129 123
M1 M5 M8 M8 M10 M10 M12
W1 25 35 35 44 44 58

Šta je MCCB?

Automatski prekidači s livenim kućištem su električni zaštitni uređaji koji su dizajnirani da zaštite električni krug od prekomjerne struje. Ova prekomjerna struja može biti uzrokovana preopterećenjem ili kratkim spojem. Automatski prekidači s livenim kućištem mogu se koristiti u širokom rasponu napona i frekvencija s definiranom donjom i gornjom granicom podesivih postavki isključenja. Pored mehanizama za isključivanje, kompaktni prekidači se mogu koristiti i kao ručni prekidači za isključivanje u slučaju nužde ili prilikom održavanja. MCCB-i su standardizirani i testirani na prekomjernu struju, prenaponski udar i zaštitu od kvara kako bi se osigurao siguran rad u svim okruženjima i primjenama. Oni efikasno rade kao prekidač za resetiranje električnog kruga kako bi isključili napajanje i minimizirali štetu uzrokovanu preopterećenjem kruga, kvarom na zemlji, kratkim spojevima ili kada struja premaši ograničenje struje.

 

Važnost lijevanog kućištaPrekidač strujnog krugas u osiguravanju električne sigurnosti

U današnjem modernom svijetu, električna energija je važan dio našeg svakodnevnog života. Od napajanja naših domova do rada industrijskih mašina, osiguranje sigurnosti i pouzdanosti električnih sistema je ključno. Prekidač u lijevanom kućištu (MCCB) je ključna komponenta koja igra važnu ulogu. U ovom blogu ćemo istražiti važnost MCCB-a u osiguravanju električne sigurnosti.

MCCB je električni zaštitni uređaj dizajniran za zaštitu strujnih kola i opreme od preopterećenja i kratkih spojeva. Obično se koristi u stambenim, komercijalnim i industrijskim primjenama kako bi se spriječilo oštećenje električnih sistema i, što je još važnije, smanjio rizik od električnih požara.

Jedna od glavnih funkcija kompaktnog prekidača (MCCB) je prekid protoka struje u slučaju preopterećenja ili kratkog spoja. Ovo je ključno za sprječavanje pregrijavanja žica i komponenti, što može dovesti do požara i katastrofalnih oštećenja. Isključivanjem strujnih krugova i prekidom napajanja, kompaktni prekidači pomažu u izbjegavanju potencijalnih opasnosti i zaštiti ljudi i imovine.

Osim toga, kompaktni prekidač (MCCB) pruža određeni nivo praktičnosti i fleksibilnosti električnim sistemima. Mogu se lako resetovati nakon kvara, što omogućava brzo vraćanje napajanja bez potrebe za zamjenom bilo kakvih komponenti. Ovo ne samo da štedi vrijeme i trud, već i minimizira zastoje i poremećaje u svakodnevnom radu.

Pored svoje funkcije sprječavanja električnih opasnosti, prekidači s lijevanim kućištem pomažu u poboljšanju ukupne efikasnosti i pouzdanosti električnih sistema. Štiteći od preopterećenja i kratkih spojeva, oni pomažu u održavanju integriteta električne opreme i produžavaju njen vijek trajanja. To zauzvrat smanjuje potrebu za skupim popravkama i zamjenama, dugoročno štedeći vrijeme i novac.

Vrijedi napomenuti da nisu svi kompaktni prekidači isti. Prilikom odabira kompaktnog prekidača za određenu primjenu, ključno je uzeti u obzir faktore kao što su nazivna struja, prekidna moć i radni napon. Ove specifikacije treba pažljivo uskladiti sa zahtjevima električnog sistema kako bi se osigurala odgovarajuća zaštita i performanse.

Osim toga, redovno održavanje i testiranje kompaktnog prekidača (MCCB) je ključno za osiguranje njegove kontinuirane efikasnosti. Redovne inspekcije i testovi mogu pomoći u identifikaciji potencijalnih problema ili habanja kako bi se po potrebi mogle izvršiti popravke ili zamjene.

Ukratko, automatski prekidači s lijevanim kućištem igraju vitalnu ulogu u osiguravanju električne sigurnosti i pouzdanosti. Štiteći od preopterećenja i kratkih spojeva, oni pomažu u sprječavanju električnih opasnosti i minimiziraju rizik od požara. Osim toga, pomažu u povećanju efikasnosti i dugovječnosti električnih sistema, što ih čini nezamjenjivom komponentom u modernim električnim instalacijama. Ulaganje u kvalitetne kompaktne prekidače (MCCB) i osiguravanje njihovog pravilnog održavanja od vitalnog je značaja za zaštitu ljudi i imovine od opasnosti električnih kvarova.


  • Prethodno:
  • Sljedeće:

  • Napišite svoju poruku ovdje i pošaljite nam je